CU8004-0000

5

2.3 LED diagnostics

LED Allocation

State

Meaning

off

no supply voltage

P10 Power

supply

shining green

5 V

DC

for downstream ports is provided

shining green

the total current of all 4 downstream ports is less than 2,5 A

P11 Current

control

shining red

the total current of all 4 downstream ports is bigger than 2,5 A

off

port not operational

shining green

port fully operational

blinking green software attention
shining red

Error condition e.g. overcurrent (port current > 1 A or short circuit)

P31

USB Port 1

blinking red

hardware attention

off

port not operational

shining green

port fully operational

blinking green software attention
shining red

Error condition e.g. overcurrent (port current > 1 A or short circuit)

P32

USB Port 2

blinking red

hardware attention

off

port not operational

shining green

port fully operational

blinking green software attention
shining red

Error condition e.g. overcurrent (port current > 1 A or short circuit)

P33

USB Port 3

blinking red

hardware attention

off

port not operational

shining green

port fully operational

blinking green software attention
shining red

Error condition e.g. overcurrent (port current > 1 A or short circuit)

P34

USB Port 4

blinking red

hardware attention