beautypg.com

Network interfaces (x102, x103), X102, x103, Additional interfaces (optional) – BECKHOFF CP32xx User Manual

Page 14: Protective earthing, 3 additional interfaces (optional), 4 protective earthing

background image

Product Description

2.5.2 Network Interfaces (X102, X103)

X102, X103

RJ-45-Connector (Ethernet 10/100/1000 Mbit)

The RJ-45 sockets (X 102, X 103) enable connection of the Panel PC to an 10/100/1000 Mbit Ethernet
network. While using the FBS-RJ45-8-GS-connector (534494, Fa. Festo AG & Co.KG) the protection
class accords to the IP65-standard.

Pin

Signal

Housing Screen
1 TD

+

2 TD

-

3 RD

+

4 NC
5 NC
6 RD

-

7 NC
8 NC

2.5.3 Additional interfaces (optional)

There are notes at the Panel PC and in the connection area which provide information about the
hardware configuration of the Panel PC at the time it was supplied.

2.5.4 Protective Earthing

The low resistance protective earthing connection of the Panel PC is established via the ground screw,
which is located in the connection area.

Malfunction possible with missing ground connection

Note

A proper ground connection of the device is absolutely necessary for the correct
function of the touchscreen.

12