Advanced Setting:

In advance setting, user can adjust the value of temperature , the value of current , username

and password(as work with software IP POWER Center)

* 8800Pro had been adjust as shipment. User can work directly as receive.

* To adjust the current , please use current meter instrument.

* For remote control in LAN by our software " IP Power Center " , user can setup "username &

password " for security concern.

Temperature :

There is temperature sensor is build inside the device . User can change / correct the

temperature value by press " Set ".

Current :

There is current meter build inside 8800Pro. To adjust the current value , user need to have a

external current meter instrument. Like ammeter , clamp multi-meter or any current meter ( as

following pictures). Please select a device with current consume over 1 amp ( range 1 ~

9 amp to do the adjustment ) .