10 Operation

© Travis Industries

4140221

100-01293

Intermittent/Continuous Pilot

This heater may run with the pilot continuously running or in intermittent mode. For most homeowners,
the intermittent mode is preferred (this saves fuel, doesn’t give off un-needed heat). However, in some
situations the homeowner may prefer to switch the heater to continuous pilot. The most typical reasons
for switching to continuous pilot are:


 Very Cold Conditions – in very cold conditions you may notice that the burner does not light quickly,

and the flames lift off the burner. If this is situation, we recommend you switch to continuous pilot.
This will create a slight draft in the vent, allowing for the burner to light quickly and draft correctly.

 Excessive Condensation on Glass After Startup – certain installations may encounter excessive

fogging on the window after startup (not just the first time the heater was started). This is an aesthetic
condition that may be remedied by switching the heater to continuous pilot.

 Cold Glass or Heater Front – in very cold conditions you may notice that the heater front and glass

become very cold. To remedy this, switch the heater to continuous pilot.

 Frequent On / Off Operation – if you are frequently turning the heater on and off, you may wish to

leave it in continuous pilot. This allows the burner to turn on more quickly, without pilot ignition delay.

Switching from Intermittent (IPI) to Continuous Pilot (CPI)

The pilot mode on this appliance is adjusted using the remote. With the remote in the off position
(thermostat off, manual off), follow the directions below to adjust the pilot mode.

Figure 4

Press the "MODE" button

when the appliance is off to

adjust the IPI/CPI.

F

F

F

NOTE: This icon appears

when the appliance is in

CPI mode.

Press the "UP" button

to activate CPI mode.

Press the "DOWN" button

to activate IPI mode.