Installation (for qualified installers only), Clearances – Avalon Firestyles 34 DVL User Manual
Page 12
![background image](https://www.manualsdir.com/files/772696/content/doc012.png)
12
Installation (for qualified installers only)
© Travis Industries
4140813
100-01294
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture and
draperies.
Minimum
Clearances
k Sidewall to Insert
4"
102mm
l Side Facing
(non-combustible)
4"
102mm
m Top Facing*
(non-combustible)
35.5"
902mm
n Mantel*
(combustible or
non-combustible)
35.5"
902mm
x Hearth Extension
(3-Piece Panel)
1.25"
32mm
x Hearth Extension
(1-Piece Panel)
0"
0mm
* Measured from the base of the insert.
NOTE: the non-combustible top facing
must extend 35.5” (902mm) above the
base of the insert or to the bottom of the
mantel (whichever is less).
Mantel Clearances
The maximum mantel depth is 12” (305mm).
NOTE: The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Side
Wall
Combustible or Non-Combustible Mantel
Combustible Top Facing
Non-Combustible
Facing
l
k
x
n
m
Mantel Height
Above Base of Insert (n)
36"(915mm)
35"(889mm)
34"(864mm)
33"(839mm)
37"+(940mm+)
32"(813mm)
31"(788mm)
0" 1" (26mm)
2" (51mm)
8" (204mm)
7" (178mm)
6" (153mm)
5" (127mm)
4" (102mm)
3" (77mm)
9" (229mm)
10" (254mm)
11" (280mm)
12" (305mm)
Maximum Mantel Depth