beautypg.com

ATI Audio MCDA112 User Manual

Page 7

background image

7

 

MCDA‐112 Manual 

Expensive components start to die at internal temperatures above 70°C (158°F). We recommend that
you maintain rack temperatures below 50°C (122°F) to prevent excessive internal temperature buildup.

POWER
If it is necessary to convert a unit wired for 115VAC to 230VAC operation, unplug the unit from the power
source, remove the cover mounting screws and locate the jumpers next to the power transformer. Clip the
jumpers 1-2 and 3-4 (don’t unsolder), jumper from 2-3 carefully soldering together the free ends of 2-3
previously clipped. This procedure is recommended to avoid soldering damage to the multi-layer PC board.

WIRING
XLR inputs for external clock sources require special controlled impedance, 110 ohm, low loss, foil shielded,
twisted pair cables. Standard audio cable is not recommended except for runs of only a few feet. Belden
and most other cable manufacturers offer special digital audio cabling for this application. BNC connectors
use 75-ohm coax (RG59). Select a cable for losses less than 20dB at 12MHz (for data rates up to 96kHz) at
the maximum distance you require. Keep cable length as short as possible, especially when working with
Super Word clock rates.

MCDA-112 SPECIFICATIONS

INPUTS
CONNECTORS

XLR female for AES3, BNC for Word Clock and Super-Word Clock

LEVEL

XLR 0.2Vp-p minimum; BNC 0.1Vp-p minimum

IMPEDANCE

Transformer isolated, balanced and floating, XLR 110 ohms, BNC
75 ohms; input terminations may be switched in or out via front
panel control

CLOCK

Filtered and reconstructed from external input signal with dual
mode PLL

SYNC FREQUENCY

22 to 216kHz

OUTPUTS
SYNC OUT CONNECTORS

12 x BNC

LEVEL

5 V TTL unloaded

IMPEDANCE

75 ohms, unbalanced

LOOP-THRU

XLR-M and BNC

INDICATORS
EXTERNAL CLOCK FORMAT

AES, Word Clock or Super-Word Clock

SAMPLE RATE

32, 44.1, 48. 88.2, 96, 176.4 or 192 kHz

OUTPUT CLOCK FORMAT

Word Clock or Super-Word Clock

INPUT TERMINATION

Terminated or Off

CLOCK SOURCE

Internal or External

POWER

Internal Supply, 115/230VAC ±10%, 50/60Hz, 10VA, IEC320 3 pin
connector

SIZE

1 RU Package, 19” (48.3cm) W x 1.75“ (4.5cm) H x 8.5” (21.6cm) D

WEIGHT

7 pounds (3.2 kg) net; 9 pounds (4.1 kg) shipping weight

WARRANTY

Limited, One Year Warranty