2.1. J2 Connector


Pin Description

Example

1

GND.— Supply signal ground

2

RTS ( To Host ) / CLK/KB.— TTL level
232 Request to send

3

RxD ( From Host ).— TTL level 232
receive data

4

CTS ( From Host ) / DATA/KB.— TTL
level 232 Clear to Send signal.

5

DATA/PC ( PS2 DATA ).

6

CLK/PC ( PS2 CLK ).

7

TxD ( To Host ).—TTL level 232
transmit data.

8

5 V DC input—Supply voltage input.

9

I/F identification . According to the
voltage level at I/F, the scanner will
automatically select a communication
Interface, when the interface selection of
scanner being set at auto-detection
mode.
The followings list the interface
selection corresponding to the various
voltage level at I/F.
I/F floating-NC: Identified as RS232
I/F short to GND: Identified as
Keyboard wedge. Wire I/F with a
4.7K then ground : Identified as USB

Wire I/F with a 4.7K then ground

R

4

4.

7K

/0

60

3

10

Trigger Switch(SW1)
To trigger off a scanning operation..

P14 of CPU is wired to the SW1 to read
the SW1 status, pressed or released.

SW1

Tack Switch

1

GND

3

GND

2

TRIGEER

4

TRIGEER

STS-KB5