AquaMAX G270VE Series User Manual
Page 10

9
thermostat is fully automatic and the burner only operates when the water
in the storage cylinder requires heating. There is no need to switch the
water heater off when it is not in use, except when you are going away for
an extended period.
The temperature adjustment dial is on the front of the gas control located
behind the front access panel of the water heater (refer to the diagram in
‘Lighting Instructions’ on page 6). The adjustment dial is marked with
numerals with each number representing a temperature difference of
approximately 10°C. When aligned with the temperature dial position
indicator on the gas control body, the dial setting corresponds
approximately to the following temperatures:
Dial Setting
1
2
3
4
5
Temperature
30°C
40°C
50°C
60°C
70°C
To adjust the thermostat:
1.
Remove front access panel by following step 2 of ‘Lighting
Instructions’ on page 6.
2.
Rotate temperature adjustment dial anticlockwise to increase or
clockwise to decrease the stored water temperature.
Warning: Hotter water increases the risk of scald injury.
3.
Replace front access panel.
Other Important Information
Going Away?
If you plan to be away from home for one or two nights, we suggest you
leave the water heater switched on. However, if you plan to stay away
more than a few nights, the gas knob can be set to the red star ‘
’ (pilot)
position to conserve energy (follow steps 1~ 3 of ‘Shut Down Procedure’ on
page 8).
Note: When switched back on, the water heater may take up to an hour to
reheat.
Safety
This water heater is supplied with a thermostat, an over temperature cut
out, a thermocouple and a combination pressure temperature relief valve.
These devices must not be tampered with or removed. The water heater
must not be operated unless each of these devices are fitted and are in
working order.