Additional electrical specifications, Input conditions, Electrical characteristics – AMETEK XT Series User Manual
Page 19
Features and Specifications
Additional Electrical Specifications
17
Additional Electrical Specifications
Input Conditions
Electrical Characteristics
Voltage Mode Transient Response
Time
<100
μs recovery to 0.05% band, for ± 50%
load change in the range of 25% to 100% of
the rated load.
Time delay from power on until
output stable
1.5 s maximum
Output Noise and Ripple
1
1. RMS value measured at bandwidth of 20Hz to 300kHz, at the rear panel terminals; points of
measurement are the positive (+) and return (-) output terminal screws of the output terminal
block.
<1 mVrms (voltage mode)
<2 mArms (current mode)
Output Noise and Ripple
1
(250 V unit only)
<5 mVrms (voltage mode)
<1 mArms (current mode)
Standard AC Input Voltage
115 Vac ± 10%, 57-63 Hz
Option M1 (Factory installed)
110 Vac ± 10%, 47-63 Hz
Option AC220
220 Vac ± 10%, 47-63 Hz
Option AC230
230 Vac ± 10%, 47-63 Hz
Option AC240
240 Vac ± 10%, 47-63 Hz
AC Input Current at 115 Vac,
60 Hz
Single unit: 1.2 A
Dual unit: 2.4 A
Triple unit: 3.6 A
Quad unit: 4.8 A
Output Hold-up Time
approx. 10 ms at nominal line (full load)
Maximum Voltage Differential
from output to safety ground
±400 Vdc
Insulation Resistance
Input to chassis: >120 M
Ω
Output to chassis: >120 M
Ω
Isolation Voltage
(Output not to exceed ±400 Vdc
from chassis potential.)
Input to output: 1350 Vac