Front Panel Menu System (firmware v1.09 and below)
Front Panel Display Messages
Legend:
Press rotary Adjust/Enter control
when no modification of the
tracking value has been made.
Mode Control State
Setting/Value
Press rotary Adjust/Enter control
Rotate rotaryAdjust/Enter control
VOL
CUR
FLD
PRT
SAV
RCL
CAP
VAP
PGM
Coarse Volt Pre-Set
Coarse Volt Tracking
Fold Delay
Select Preset
Select Preset
OVP
UVP
Overheat Protection
Shutdown Logic
UVP Coarse Adjust
UVP Fine Adjust
On/Off
1/0
USB
LAN
GPIB
RS-232
RS-485
Local Lock
Address (1-30)
Address (1-30)
On/Off
Data Rate
Data Rate
Off
Voltage Isolated
Voltage Non-Isolated
Resistive Isolated
Resistive Non-Isolated
Off
Voltage Isolated
Voltage Non-Isolated
Resistive Isolated
Resistive Non-Isolated
Current APG Level
Voltage APG Level
Address (1-30)
Address (1-30)
Address (1-30)
Voltage APG Level
Voltage APG Level
Voltage APG Level
Current APG Level
Current APG Level
Current APG Level
OVP Coarse Adjust
OVP Fine Adjust
Fine Volt Pre-Set
Fine Volt Tracking
CV
CC
None
Fold Delay
Coarse Current Pre-Set
Coarse Current Tracking
Fine Current Pre-Set
Fine Current Tracking
Slave
Address (1-30)
0
Negative Polarity
1
Positive Polarity
AnPR
Analog Programming
AS
Power On Autostart
AvAS
Auxiliary Autostart
CAPr
Current Analog Programming
CLr
Clear
CC
Constant Current
COn7
Controller
CU
Constant Voltage
CRPC
Coarse Current Pre-set Mode
CrPU
Coarse Voltage Pre-set Mode
CShr
Current Share (same as CUrrShAr)
Curr
Current
CUrrShAr
Current Share (same as CShr)
deLa
Fold Delay
FOLD
Foldback protection triggered
FLA
Flash
FNPC
Fine Current Pre-set Mode
FNPU
Fine Voltage Pre-set Mode
FLd
Setting up Foldback trigger
gpib
GPIB Interface
HbPS
Data rate (Kbps)
In
Interlock
H rS
Hard Reset
LE C
Current APG Level
LE U
Voltage APG Level
Loc
Lock
LOCL
Local
OCP
Over Current Protection
O7P
Over Temperature Protection
OUP
Over Voltage Protection
OvPF
Over Voltage Protection fine adjustment
OUPC
OVP Calibration
OU7P
Output Protection
POL
Polarity
PRO
Protection mode
PSU
Power Supply Unit
r IS
Isolated Resistive Analog Programming
rCL
Recall User Setting Memory Locations
RE
Remote Programming/Interface
rnIs
Non-Isolated Resistive Analog
SAFE
Safe
Sd
Shutdown
sLa
Slave Remote Interface
S rS
Soft Reset
U Is
Isolated Analog Voltage Programming
UN Is
Non-Isolated Analog Voltage
UUP
Under Voltage Protection Coarse
UUPF
Under Voltage Protection Fine Adjustment
UAPr
Voltage Analog Programming
UOL
Voltage