beautypg.com

AMETEK XG 850 Watt Series Quick Start 1.09 and earlier User Manual

Page 2

background image

Front Panel Menu System (firmware v1.09 and below)

Front Panel Display Messages

Legend:

Press rotary Adjust/Enter control

when no modification of the
tracking value has been made.

Mode Control State

Setting/Value

Press rotary Adjust/Enter control

Rotate rotaryAdjust/Enter control

VOL

CUR

FLD

PRT

SAV

RCL

CAP

VAP

PGM

Coarse Volt Pre-Set

Coarse Volt Tracking

Fold Delay

Select Preset

Select Preset

OVP

UVP

Overheat Protection

Shutdown Logic

UVP Coarse Adjust

UVP Fine Adjust

On/Off

1/0

USB

LAN

GPIB

RS-232

RS-485

Local Lock

Address (1-30)

Address (1-30)

On/Off

Data Rate

Data Rate

Off

Voltage Isolated

Voltage Non-Isolated

Resistive Isolated

Resistive Non-Isolated

Off

Voltage Isolated

Voltage Non-Isolated

Resistive Isolated

Resistive Non-Isolated

Current APG Level

Voltage APG Level

Address (1-30)

Address (1-30)

Address (1-30)

Voltage APG Level

Voltage APG Level

Voltage APG Level

Current APG Level

Current APG Level

Current APG Level

OVP Coarse Adjust

OVP Fine Adjust

Fine Volt Pre-Set

Fine Volt Tracking

CV

CC

None

Fold Delay

Coarse Current Pre-Set

Coarse Current Tracking

Fine Current Pre-Set

Fine Current Tracking

Slave

Address (1-30)

0

Negative Polarity

1

Positive Polarity

AnPR

Analog Programming

AS

Power On Autostart

AvAS

Auxiliary Autostart

CAPr

Current Analog Programming

CLr

Clear

CC

Constant Current

COn7

Controller

CU

Constant Voltage

CRPC

Coarse Current Pre-set Mode

CrPU

Coarse Voltage Pre-set Mode

CShr

Current Share (same as CUrrShAr)

Curr

Current

CUrrShAr

Current Share (same as CShr)

deLa

Fold Delay

FOLD

Foldback protection triggered

FLA

Flash

FNPC

Fine Current Pre-set Mode

FNPU

Fine Voltage Pre-set Mode

FLd

Setting up Foldback trigger

gpib

GPIB Interface

HbPS

Data rate (Kbps)

In

Interlock

H rS

Hard Reset

LE C

Current APG Level

LE U

Voltage APG Level

Loc

Lock

LOCL

Local

OCP

Over Current Protection

O7P

Over Temperature Protection

OUP

Over Voltage Protection

OvPF

Over Voltage Protection fine adjustment

OUPC

OVP Calibration

OU7P

Output Protection

POL

Polarity

PRO

Protection mode

PSU

Power Supply Unit

r IS

Isolated Resistive Analog Programming

rCL

Recall User Setting Memory Locations

RE

Remote Programming/Interface

rnIs

Non-Isolated Resistive Analog

SAFE

Safe

Sd

Shutdown

sLa

Slave Remote Interface

S rS

Soft Reset

U Is

Isolated Analog Voltage Programming

UN Is

Non-Isolated Analog Voltage

UUP

Under Voltage Protection Coarse

UUPF

Under Voltage Protection Fine Adjustment

UAPr

Voltage Analog Programming

UOL

Voltage

Part Number M370078-04 Rev D January 2009

© 2007-2009 AMETEK Programmable Power, Inc. All rights reserved.

www.programmablepower.com

This manual is related to the following products: