Post Download Issues
When a revision change takes place several errors may appear at power up, dependent on
previous revision. To clear the errors send the SCPI commands from the interface screen of the
GUI or use the Flash Loader utility program command line as instructed below based on the error
reported:
1. Always perform this step, even if no errors are reported:
Using the interface:
Using the Flash loader program or LxGui program (establish communication with the unit
first) command line, send the following command:
OUTP:PON:STATE
RST
Power down the unit and power back up.
Re-establish connection over the bus.
If power settings other than factory defaults (60 Hz, low voltage range, output open, current
limit max) are required, set frequency and voltage range to the desired power up conditions
and save to register 0, send following commands:
*SAV 0
OUTP:PON:STATE RCL0
-------------------------------------- OR --------------------------------------
Using the Front Panel
Press MENU key until CONFIGURATON is shown.
Select CONFIGURATION by pressing ENTER key and scroll to POWER ON entry using up
down arrow keys.
If set to REG0 selection, change to RST selection using Voltage or Frequency knob.
Power down the unit and power back up.
If power settings other than factory defaults (60 Hz, low voltage range, output open, current
limit max) are required, set frequency and voltage range to the desired power up conditions
and save to register 0 using CONFIGURATION menu, SAVE REG# 0 entry. Press ENTER
key to save settings to reg 0.
Return to PON REG entry and set the power on state to RCL0.
If other setup registers have been used before the firmware upgrade, they will have to
be reset as well by setting the desired settings and re-saving to these registers.
2. If waveform memory error appears, send TRACE:DEL:ALL using the command line of the
Flash download utility.
3. If initial memory lost message appears, send PONS:CLOCK STAN.
4. If the model changed to Ls from Lx, send SYST:MOD "Lx"
California Instruments
Firmware Update Instructions