beautypg.com

Quick start installation guide sitesync iq, Wireless clock system, Connect cables to the system controller – American Time CDMA 5 Watt Standard User Manual

Page 2: Unpack the box, Check the components, Choose your location, Use the setup wizard

background image

QUICK START INSTALLATION GUIDE

SITESYNC IQ

®

WIRELESS CLOCK SYSTEM

Connect cables to the system controller

A.

Connect the CDMA antenna to the CDMA ANT port.

B.

Connect the System Controller power supply to the POWER

INPUT port.

C.

Connect the magnet mount TX antenna to the TX ANT port.

Plug 110v cord into power source. Turn the POWER SWITCH on

the back of the system controller to the on position.
Note: If your system controller supports more than one time sync

option, refer to the SiteSync IQ Installation & Operation Manual for

detailed instructions.

MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO CDMA=S

1

4

5

Unpack the box

1. Remove the components and system controller from the box.

Save the packing materials in case you need them later.

Check the components

Your system kit comes with:

• System Controller

• Hinged screw-on CDMA antenna

(A)

• Power supply

(B)

• Magnetic mount TX antenna with 12' cable

(C)

• Installation & Operation Manual

Choose your location

• Choose a location for the system controller that receives good

cellular reception. The easiest way to check reception is to

check signal strength on a cell phone.

Avoid high voltage equipment when choosing a location.

• Choose a location for your magnetic mount TX antenna either

outside or inside at the highest central location in your facility.

The TX antenna must be located at least 4' away from

the system controller and must always point up or down,

never horizontal! The cable length cannot be extended.

2

3

4 ft

minimum

TUE FEB 09 2010
10:38:06 AM USCT
American Time & Signal
Status=AUTO CDMA=Y

CDMA signal

to facility

CDMA Ant

signal in

TX Ant signal

out to clocks

System controller located

high & central

A

C

B

To local

power

(110vac)

Use the Setup Wizard

1. Press

1 to start the Setup Wizard

(Page 9 in Installation Manual)

2. Create a 4 digit

User Lock or enter 0000 to disable this

feature. Press

O

.

Tip: Record this password.

3. Create a 4 digit

Service Lock (for advanced features) or enter

0000 to disable this feature. Press

O

.

Tip: Record this password.

4. Select local time zone by using the

<>

keys. Press

O

.


USET=Eastern USCT=Central USMT=Mountain USPT=Pacific

Note: There are 40 options to choose from.

5. Press

8

to select automatic DST (Daylight Saving Time) or

0

to disable DST if your location doesn't observe DST.

Press

O

6. Press

1

for 12-hour mode - AM/PM (1:00PM).

Press

2

for 24-hour mode - Military (13:00).

7. To confirm proper set up, press

8

to sync.

• If successful, “CDMA Sync Successful” will display

• If not successful, “CDMA Sync Failed” will display. Re-try

by pressing

8

again.

8. “Setup Wizard Successfully Completed” will display.

The system controller now shows the correct time and date. You

will no longer be prompted on power-up for setup information.

9.

Verify the unit is transmitting. TX should display for about

three seconds every 30 seconds (approximately the top and

bottom of every minute) in the bottom right corner of the

screen.

MON MAR 10 2014

10:38:06 AM USCT

American Time

Status=AUTO

TX

Set Menu LOCAL

Time Zone Code: 05

99=Custom USCT

<>=Scroll

OK=Accept

Note: Screen

will advance

immediately