Technical data temperature sensors

Platinum resistance

Pt 1000

Sensor diameter/type

mm

Standard: 5,0 (DS according to EN 1434); other sizes on demand

Temperature range

°C

0 - 105

Cable length

m

1,5 (opt. 5)

Installation

forward

temp.-sensor

by direct immersion or by immersion sleeves (in case of existing measuring points )

return

temp.-sensor

by direct immersion or by immersion sleeves (in case of existing measuring points);

optionally integrated in flow sensor

ZENNER International GmbH & Co. KG declares
that this product with the number of the EC type-
examination certificate DE-12-MI004-PTB010
complies with the requirements of the EC direc-
tives 2004/22/EC (Measuring instruments direc-
tive) and 89/336/ EEC (electro-magnetic compa-
tibility).

Electro-magnetic interference

zelsius

®

C5-ISF fulfils the national and interna-

tional requirements for interference resistance.
To avoid malfunctions due to other interfer-
ences, do not install fluorescent lamps, switch
cabinets or electric devices such as motors or
pumps in the immediate vicinity of the meter
(minimum distance 1 m). Cables leaving the
meter should not be laid parallel to live cables
(230V) (minimum distance 0.2 m).

Care instructions

Clean plastic surfaces with a damp cloth only.
Do not use any scouring or aggressive cleaning
agents! The device is maintenance-free during
the service life. Repairs can only be made by the
manufacturer.
The most up-to-date information about this pro-
duct and of our installation notice can be found at

www.zenner.com.

Pulse inputs and outputs
(optional)

By meters with pulse outputs, the pulse value
can be called up in the display (see the display
overview, Level 4).
The pulse value of the outputs is permanently set
and corresponds with the last position of the as-
sociated display value.

Example:

Output 1 = energy output
Energy display = XXXXX.XXX
Last position = 0.001 MWh = 1 kWh
Output pulse = 1 kWh