AES Outputs: Pinout and Drive Capabilities 
 
Two transformer balanced, isolated sets of AES outputs are available on the DB25 connector. 
The wiring follows the TASCAM convention, as shown in the table below: 
 
Output Pair
Hot
Cold
Ground
A1
A1
A1
A1
(Chs 1
(Chs 1
(Chs 1
(Chs 1&2)
&2)
&2)
&2)
24
12
25
A2
A2
A2
A2
(Chs
(Chs
(Chs
(Chs 3
33
3&
&
&
&4
44
4))))
10
23
11
A3
A3
A3
A3
(Chs
(Chs
(Chs
(Chs 5&6
5&6
5&6
5&6))))
21
9
22
A4
A4
A4
A4
(Chs 7&8
(Chs 7&8
(Chs 7&8
(Chs 7&8))))
7
20
8
B1 (Chs 1&2)
B1 (Chs 1&2)
B1 (Chs 1&2)
B1 (Chs 1&2)
18
6
19
B2 (Chs 3&4)
B2 (Chs 3&4)
B2 (Chs 3&4)
B2 (Chs 3&4)
4
17
5
B3 (Chs 5&6)
B3 (Chs 5&6)
B3 (Chs 5&6)
B3 (Chs 5&6)
15
3
16
B4 (Chs 7&8)
B4 (Chs 7&8)
B4 (Chs 7&8)
B4 (Chs 7&8)
1
14
2
 
 
The DS8000’s digital outputs utilise industry standard drivers and circuitry to ensure that the 
performance of the digital outputs is as widely compatible as possible with other professional 
equipment. 
 
The pairs of outputs will drive into 110R standard loads, tested up to cable distances of 100 
metres. 
 
Please ensure that high quality AES specified cable is used for all connections — the use of 
poor cables on one AES pair may have an adverse effect on the other pair (incorrect 
terminations/loads on A1 may have an affect B1 and so on). 
 
If you are unsure about what type of cable to use, please feel free to give us a call to discuss 
your application or email 
.