Xilica XD Series User Manual
Page 5

COMMAND AND CORRESPONDING VALUE TABLES
AUDIO COMMAND
ID
Data Min
Data Max
Value Min
Value Max
Value Step
Meter MTR0
Mute MUT0
0
1
OFF
ON
Mix
Gain MIC0
0
15
0dB 45dB 3dB
Signal Level
LVL0
0
220
-40dB
+15dB
0.25dB
Signal Polarity
POL0
0
1
+
-
Signal Delay
DLY3
0
62400
0ms
650ms
1/96ms
EQ Type
EQT0
0
4
PEQ / LO-SH / HI-SH / AP-1 / AP-2
EQ Frequency
EQF0
0
29980
20Hz
30000
1Hz
EQ Bandwidth
EQB0
0
359
0.02 oct / 0 deg
3.61oct/179.5 deg
0.01oct/ 0.5 deg
EQ Level
EQL0
0
180
-30dB
+15dB
0.25dB
EQ Bypass
EQb0
0
1
OFF
ON
GEQ Level
EQL1
0
180
-30dB
+15db
0.25dB
GEQ Bypass
EQb1
0
1
OFF
ON
Crossover Type
XRT0
0
3
OFF / BUTWRTH / LINK-RI / BESSEL
Crossover Frequency
XRF0
0
29980
20Hz
30000
1Hz
Crossover
Slope
XRS0
0
7
6dB 48dB 6dB
FIR Type
XFE0
0
1
OFF / FIR
FIR Frequency
XFF0
0
29980
20Hz
30000
1Hz
Compressor Threshold
CMT0
0
80
-20dBu
+20dBu
0.5dBu
Compressor Attack
CMA0
0
106
0.3ms
100ms
0.1ms / 1ms
Compressor Release
CMR0
0
4
2x / 4x / 8x / 16x / 32x
Compressor
Ratio
CMX0
0
39
1 40 1
Limiter Threshold
LMT0
0
80
-20dBu
+20dBu
0.5dBu
Limiter Attack
LMA0
0
106
0.3ms
100ms
0.1ms / 1ms
Limiter Release
LMR0
0
4
2x / 4x / 8x / 16x / 32x
Mixer MIX0
0
161
OFF
0.0dB
0.25dB
Channel Name
CHN0
0
84
'_'
';'
CHARACTER CODE MAP
_ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789abcdefghijklmnopqrstuvwxyz-<>?,./~!@#$%^&*()=+';