9. TROUBLESHOOTING
BEFORE CALLING FOR SERVICE
The following are not defects.
10. SPECIFICATIONS
NOTE: Dehumidifying capacity will vary according to temperature
and humidity of the room.
CONTAINS FLUORINATED GREENHOUSE GASES COVERED BY
THE KYOTO PROTOCOL.
HERMETICALLY SEALED SYSTEM
3
ENGLISH
SYMPTOM
Unit does
not work.
FULL lamp is
ON even the
water tank is
empty.
The product
does not de-
humidify.
Operation
sound is
loud.
The drain
water is
leaked.
CAUSE
- Power cut.
- The plug has been
plugged improperly.
- The FULL LAMP is
ON. Tank is full.
- The DEFROST LAMP
is ON.
- The tank is not insert-
ed properly.
- The float of tank is not
placed properly.
- The filter is dusty or air
outlet is clogged.
- Surrounding tempera-
ture and humidity are
low.
- The filter is dusty
- The unit operates on
the rough place.
- The unit leans.
- Move the unit with wa-
ter in the tank.
- The float is not in the
proper position.
- Take the water tank
out soon after stop-
ping the operation.
SOLUTION
- Wait for power to be
supplied again.
- Plug in again.
- Remove the drain wa-
ter from the drain
tank.
- When the room tem-
perature is under
12˚
C, the heat ex-
changer is sometimes
frosted. And the unit
starts defrosting mode
automatically. During
this mode, DEFROST
LAMP is ON, and wait
for a while.
- Take the water tank
out once, and push it
back to the proper po-
sition.
- Place the float in the
proper position.
- Clean the filter and air
outlet.
- As the temperature
and humidity are low-
er, the amount of de-
humidification is also
lower.
- Clean the filter.
- Operate at the flat
place.
- Operate at the flat
place.
- Remove the water at
first, and then you can
move the product.
- Place the float proper-
ly.
- The product keeps
draining even the unit
stops operating. Wait
for approx. 5mins.
MODEL
TD-C100
DEHUMIDIFYING CAPACITY
10 L/D (30˚C, 80%RH)
POWER SOURCE
Single Phase 220-240V, 50Hz
POWER CONSUMPTION
205 W
OPERATING CURRENT
0.8A
AIR FLOW (MAX.)
45 m
3
/h
OPERATING TEMP. RANGE
5˚C ~ 32˚C
DIMENSIONS (WxHxD)
230 x 386 x 230 mm
WEIGHT
8.5kg
COMPRESSOR
ROTARY
REFRIGERANT
R-134A / 110g
A hissing noise or hollow
sound:
A squeaking noise:
Odor:
The unit does not start nor
change operation mode
immediately:
e
This sound is generated from the
refrigerant flowing within pipes.
e
This noise is generated from the
unit when it is expands or con-
tracts with temperature changes.
e
Such odor as tobacco, cosmet-
ics, or foods may accumulate in
the unit.
e
To prevent overloading the com-
pressor motor, the unit will be
stopped for more than 3 minutes.
TD-C100.qxd 14.6.2 16:26 ページ 3