beautypg.com

Installation – Televes T.0X Encoder TWIN HDMI/Composite CVBS - COFDM/QAM User Manual

Page 4

background image

Installation

1.

Install all units in the rack and connect them as shown in Figure 1.

Figure 1

2.

The audio and video input signals connect to the back of the

modules.

Figure 2

3.

If a network is available that provides IP addresses through DHCP,

connect the encoders to the network as shown in Figure 3. If such a

network is not available, then a computer will need to be connected

as shown in Figure 4.

NETWORK

with

DHCP server

Figure 3 - Rack with DHCP server.

4.

Power on the units.

Figure 4 - Rack without DHCP server.

5.

Connect the programmer to each unit and set a unique number in

the “# ID” field according to the order of installation of the units in

the rack.

- # ID -

0001

- # ID -

0006

Figure 5 - Set a # number different for each unit.

6.

Connect the programmer to a unit, usually the first one, and read

the IP address.

Each unit can work as a master controller for the other units. All units

can be configured by connecting to only one.

- NETWORK -

IP ADDRESS

001.001.

005.097

Figure 6 - Read the IP address of one unit.

7.

If a network was connected in Step 3 then proceed to step 8. If not,

set the address of you computer as follows:

IP value = 172.20.0.2

netmask = 255.0.0.0

gateway = 172.20.0.3

NOTE: ThedefaultfactoryconfigurationoftheunitshasanIPaddressin

thisrange(itshouldbedifferentforeachunit).Ifaunitwasever

providedanaddressbefore,manuallyorthroughDHCP,thisunique

address may no longer exist. Resetting to IP factory defaults, will

returntheoriginaluniqueprivateaddressthough.

8.

In your web browser, enter the IP address from Step 6 as the URL.

A login prompt will appear. By default the parameters are:

Login: encoder

Password: encoder