b. Configuration menu 2

Next menu allows you to select the version of the

output NIT and the type of LCN (Logical Channel

Number).

NIT’s version can be selected between 0 and 31 or

“AUT”, in which case the output NIT will have the

same version as the input.

CONFIG.

NIT vers:AUT

LCN:Generic

Regarding the Logical Channel Number (LCN),

no all receivers understood in the same way this

information. Some countries use some variation

on the standard to be applied to this configuration

to work properly. Possible values are Generic, UK,

Nordig 1, Nordig 2.

c. Identifier menu

Some DVB-T receivers can present problems

receiving transmodulator channels which share

the same identifier (transport_stream_id). To avoid

these cases the user can change the following DVBT

output multiplex identifiers: transport_stream_id

(ts_id), network_id (n_id) and original_network_id

(on_id).

You can choose Auto mode (the identifiers do not

change) or Manual mode.

When switching from Auto mode to Manual the

identifiers received by satellite are displayed and

the user can change them.

NIT IDs

Auto

IDs Manual

ts_id: 0x04fc

n_id: 0x055f

on_id: 0x055f

d. Temperature measurement

menu

The following menu provides an indication of

the unit’s current temperature as well as the

maximum recorded. The maximum can be reset by

pressing the key .

MEDIDAS

Act: 04

Max: 05

reset

MONITOR

Now: 04

Max: 05

reset

MESSUNGEN

Akt: 03

Max: 04

reset

MESURES

Act: 03

Max: 04

reset

MISURE

Pre: 03

Max: 04

reset

The recommended operating margins are as

follows:
• Optimum operation : 0-6
• High temperature: 7-8
• Excessive temperature: 9-10

If the maximum recorded is outside the optimal

range the installation should be adjusted to try to

lower the temperature.

If the DVBS2-COFDM (CI) modules have been

installed in a housing ref. 5069 and the temperature

of one of the modules is outside of the optimal

operating range, the ventilation unit will have to be

installed ref. 5334. To check whether this change is

effective the maximum can be reset and its value

checked after a given time.

e. Versions menu

In this menu the user is shown the firmware

versions for the unit and the COFDM (FPGA)

modulator.

VERSION

Unidad:

1.05

1.04

VERSION

Unit:

1.05

1.04

VERSION

Modul:

1.05

1.04

VERSION

STS:

1.05

1.04

VERSION

Modulo:

1.05

1.04

f. CAM (MMI) user interface menu

(only ref. 563301)

This menu allows access to the conditional access

module (CAM) user interface, for example, to check

versions or card rights: