B. configuration menu 2, C. identifier menu, D. temperature measurement menu – Televes DVB-S2 COFDM User Manual
Page 17: E. versions menu, F. cam (mmi) user interface menu
EN
17
b. Configuration menu 2
Next menu allows you to select the version of the
output NIT and the type of LCN (Logical Channel
Number).
NIT’s version can be selected between 0 and 31 or
“AUT”, in which case the output NIT will have the
same version as the input.
CONFIG.
NIT vers:AUT
LCN:Generic
Regarding the Logical Channel Number (LCN),
no all receivers understood in the same way this
information. Some countries use some variation
on the standard to be applied to this configuration
to work properly. Possible values are Generic, UK,
Nordig 1, Nordig 2.
c. Identifier menu
Some DVB-T receivers can present problems
receiving transmodulator channels which share
the same identifier (transport_stream_id). To avoid
these cases the user can change the following DVBT
output multiplex identifiers: transport_stream_id
(ts_id), network_id (n_id) and original_network_id
(on_id).
You can choose Auto mode (the identifiers do not
change) or Manual mode.
When switching from Auto mode to Manual the
identifiers received by satellite are displayed and
the user can change them.
NIT IDs
Auto
IDs Manual
ts_id: 0x04fc
n_id: 0x055f
on_id: 0x055f
d. Temperature measurement
menu
The following menu provides an indication of
the unit’s current temperature as well as the
maximum recorded. The maximum can be reset by
pressing the key .
MEDIDAS
Act: 04
Max: 05
reset
MONITOR
Now: 04
Max: 05
reset
MESSUNGEN
Akt: 03
Max: 04
reset
MESURES
Act: 03
Max: 04
reset
MISURE
Pre: 03
Max: 04
reset
The recommended operating margins are as
follows:
• Optimum operation : 0-6
• High temperature: 7-8
• Excessive temperature: 9-10
If the maximum recorded is outside the optimal
range the installation should be adjusted to try to
lower the temperature.
If the DVBS2-COFDM (CI) modules have been
installed in a housing ref. 5069 and the temperature
of one of the modules is outside of the optimal
operating range, the ventilation unit will have to be
installed ref. 5334. To check whether this change is
effective the maximum can be reset and its value
checked after a given time.
e. Versions menu
In this menu the user is shown the firmware
versions for the unit and the COFDM (FPGA)
modulator.
VERSION
Unidad:
1.05
1.04
VERSION
Unit:
1.05
1.04
VERSION
Modul:
1.05
1.04
VERSION
STS:
1.05
1.04
VERSION
Modulo:
1.05
1.04
f. CAM (MMI) user interface menu
(only ref. 563301)
This menu allows access to the conditional access
module (CAM) user interface, for example, to check
versions or card rights: