beautypg.com

Troubleshooting guide – DeVillbiss Air Power Company W1217 User Manual

Page 9

background image

9

TROUBLESHOOTING GUIDE

PROBLEM

Motor will not start and there is no
humming sound

Power source circuit continues to
trip or blow fuses

Motor hums but will not start

Unit does not reach required
pressure

Units cycles automatically without
triggering the gun.

Continuous tripping of a G.F.C.I.
circuit.

1. Not plugged in.
2. "RESET" button on GFCI not

pushed.

3. Circuit breaker has tripped or

fuse is blown.

1. Too much load already on

circuit.

1. Extension cord is too long or of

improper gauge, causing voltage
drop.

2. Pump is stuck due to dirt,

mineral build up, or ice.

3. Motor malfunction

1. Restricted, or insufficient water

supply.

2. Clogged nozzle.

1. Water leak in high pressure fittings,

hose, or gun

1. Unit could have an electrial short.

1. Plug in.
2. Push "RESET" button.
3. Reset breaker or replace fuse.

1. Reduce load on circuit.
2. Try another G.F.C.I. circuit.

1. See section on extension cords

(See page 6).

2. Unplug unit. If temp is below

freezing do not use. Thaw in a
warm area.

3. Take to authorized service

center (See page 2)

1. Check supply hose, faucet and

inlet screen. Must be connected
to water source which provides
1.7 gal. water per minute.

2. See nozzle cleaning section.

1. New gun/hose assembly.

1. Take to nearest AWSC.

REMEDY

CAUSE

This manual is related to the following products: