beautypg.com

Mcs system specifications – Oxmoor MCS User Manual

Page 6

background image

Oxmoor Corporation, LLC, 309 Cahaba Valley Parkway, Birmingham, AL 35124 USA Toll Free: 1-800-262-6898

Phone: 205-982-8200 Fax: 205-982-8250 E-mail: [email protected] Internet: www.oxmoor.com

AUDIO IN

Type ................................................. Electronically Balanced (RF Suppressed)

Connectors ....................................... Screw Terminal Blocks

Input Impedance ............................... 80 k Ohms

Maximum Input Level ....................... +24 dBu

AUDIO OUT

Type ................................................. Electronically Balanced

Connectors ....................................... Screw Terminal Blocks

Source Impedance ............................ 20 Ohms (10 Ohms Each Side)

Maximum Output Level

(Ref. 1 kHz @ rated THD)

Terminated w/600 Ohms .................. +18 dBm

Unterminated ................................... +26 dBu

FREQUENCY RESPONSE

20 Hz to 20 kHz ............................... +0, -0.3 dB

-3 dB Points, Ref. 1 kHz .................... 4 Hz to 70 kHz (+4 dBm Output)

HUM AND NOISE

Ref. +4 dBm Output @ Unity Gain ...... -85 dB (20 Hz to 20 kHz, Unweighted)

DISTORTION

Total Harmonic (THD + NOISE)

Ref. +4 dBm Output @ Unity Gain ...... -80 dB/0.01% (20 Hz to 20 kHz)

Ref. +4 dBm Output @ Unity Gain:

SMPTE IMD ............................... -80 dB/0.01%

Transient IMD ........................... -80 dB/0.01%

CROSSTALK & OFF ISOLATION

Channel to Channel .......................... -85 dB (@ 1 kHz)

Driven Input to Off Output ................. -85 dB (@ 1 kHz)

TRIM POT GAIN RANGE

Ref. 0 dBu Output .............................

±

15 dB

VOLUME CONTROL

Type ................................................. Oxmoor's RC-16

Connector ........................................ Screw Terminal Blocks

LOGIC

Connector ........................................ Screw Terminal Blocks

Input Type ........................................ Active Low, Internally Pulled Up

Input Protection ................................ 1/2 Max. Line Voltage, 12 kV Static

Logic Action ...................................... Momentary Closure to Common

Logic Levels (at Terminal Block) ....... Low < .8 Volts, High > 2.4 Volts

Maximum Sink Current ..................... 1 mA

Maximum Cable Length .................... 600m (2000 ft), #22 AWG

TALLY

Connector ........................................ Screw Terminal Blocks

Output Type ...................................... Open-Collector Darlington to Common

Max. Sink Current ........................... 500 mA

Max. Voltage .................................... 50 VDC

MCS SYSTEM SPECIFICATIONS

Specifications subject to change without notice.

Printed 7/01