2 arrayed speaker systems (cluster), Arrayed speaker systems (cluster) – KLING & FREITAG K&F CA 106 User Manual
Page 11

User's Manual
CA 106
KLING & FREITAG GMBH ©1995 - 2006
Version 5.1, 09.11.2006
Page 11 of 26
7.2
Arrayed Speaker Systems (Cluster)
If the loudspeakers are operated through the optional K&F C2 System Controller, we
recommend turning on the ‘Top Low Cut’ switch for clustered operation. Thus the fre-
quency response for this application can be optimised (see also K&F C2 User's Manual).
When operating the systems without the K&F C2 System Controller in a clustered con-
figuration, the signal level of frequencies below 300 Hz should be reduced by 3-4 dB.
Standing speaker
Horn not rotated
Horn rotated
Recommended horizontal
array configuration for
extending the horizontal
coverage angle, e.g. to
cover a wide area
60°
40°
Recommended vertical
array configuration for
extending the vertical cov-
erage angle, e.g. for reach-
ing balconies or increasing
the sound pressure level
when covering greater
distances
40°
60°