Installation

8

Ilumipanel 40 IP Optic WW User Manual Rev. 3

The Ilumipanel
40 IP Optic WW
must be linked
using DMX cable

in a daisy chain (serial)
fashion. To comply with
the EIA-485 standard, no
more than 32 products
should be connected on
one daisy chain without
using a DMX optically
isolated splitter. Doing
otherwise may result in
deterioration of the digital
DMX signal.

USITT
recommends
limiting the total

length of the DMX cable
(from the first
product/controller to the
last product) to 300~455
m (985~1,500 ft).

Disconnect the
product from the
AC power before

opening it.

The signal cable
must match or
exceed the

electrical characteristics
of the Belden® 9841
cable for EIA RS-485
applications. You may
also use CAT5, 5e, or
CAT6 LAN cable.

DMX Linking

You may link the Ilumipanel 40 IP Optic WW to a DMX controller using a standard DMX
serial connection. If using other DMX products compatible with the Ilumipanel 40 IP Optic
WW, you can control each individually with a single DMX controller.
If you are not familiar with the DMX standard, or if you need information about the DMX
cables needed to link the Ilumipanel 40 IP Optic WW to a DMX controller, you may download
the “DMX Primer” from the ILUMINARC® website at

http://www.iluminarc.com/reports/dmx-primer

.

DMX Modes

The Ilumipanel 40 IP Optic WW uses the standard DMX data connection for its SOLID mode.
Refer to the

Introduction

chapter for a brief description of this mode. Refer to the

Operation

chapter to learn how to configure the Ilumipanel 40 IP Optic WW to work in these modes. The

DMX Values

section provides detailed information regarding the DMX mode.

DMX Mode

DMX Address

SOLID

512

Signal Wiring

To provide signal for the Ilumipanel 40 IP Optic WW, you can connect the bare-ended,
IP67-rated signal cable from the product to two IP67-rated signal connectors (DMX In/DMX
Out) or use an IP67-rated junction box. In this case, make sure to use

IP67-rated conduit.

Protocol Connectivity

The Ilumipanel 40 IP Optic WW uses the uses the USITT DMX 512 Protocol. The procedure
below illustrates the recommended connection method.