Page 6: Detail view b (1.5 : 1), Future automation, Contact closure, Instruction sheet, Electric advance & drop

1
8
pins
There are a number of LEDs
which will light up when the
corresponding contact closure
connections are shorted together.
A red LED will light up when the
emergency stop link is removed.
B
DETAIL B
Contact Closure
Use an RJ45 connector in the
CC1 socket on the control box
to operate via contact closure.
Momentary short to ground
will make device go IN. CC1
Momentary short to ground
will make device go OUT. CC2
When shorted to ground,
stops device in current position. CC3
When shorted to ground, device will go OUT.
When short removed, device will go IN. CC4
Momentary short to ground will switch the
device between states of IN / OUT. CC5
When 12V is attached, device will go OUT.
When 12V is removed, device will go IN.
DEVICE IN
DEVICE OUT
DEVICE STOP
DEVICE IN LATCHED
GROUND
12V LATCH
12V SUPPLY CURRENT LIMITED
BR
W/BR
G
W/BL
BL
W/G
O
W/O
BR
W/BR
O
W/BL
BL
W/O
G
W/G
8
7
6
5
4
3
2
1
ACTION
DESCRIPTION