Al675 udc1 actuator lift – Future Automation AL675 User Manual
Page 14

In
st
al
la
ti
o
n
:
E
le
ct
ric
al
C
on
ne
ct
io
n
Page 13 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
AL675 UDC1 Actuator Lift
SLQV
Contact Closure
- Use an RJ45 connector in the
appropriate socket on the control
box to operate via contact closure
568A
568B
1
12V SUPPLY
12V SUPPLY - CURRENT LIMITED
W/G
W/O
2
12V LATCH
When 12V attached, device will go OUT.
When 12V removed device will go IN.
G
O
3
GROUND
GROUND
W/O
W/G
4
PIN 4 NOT USED
BL
BL
5
DEVICE LATCH
Momentary short to GROUND (pin 3), stops
device in current position.
W/BL
W/BL
LED 4
6
DEVICE STOP
Momentary short to GROUND (pin 3), stops
device in current position.
O
G
LED 3
7
DEVICE OUT
Momentary short to GROUND (pin 3), makes
device go OUT.
W/BR
W/BR
LED 2
8
DEVICE IN
Momentary short to GROUND (pin 3), makes
device go IN.
BR
BR
LED 1
PIN
DESCRIPTION
ACTION
WIRE / CABLE
CONTACT CLOSURE
LED INDICATOR