beautypg.com

Settriggercount, Settriggerlength, Settriggermode – Dataman 570 Series User Manual

Page 17

background image


Development kit for DATAMAN 570 series

Programmer’s Guide


level – determines quantization level (0 to 255), which will be considered as

threshold

Return value: -

3.3.6. SetTriggerCount

Sets amount of trigger events necessary to start acquisition on the selected trigger
level.

void __declspec(dllimport) __stdcall SetTriggerCount(int level, int amount);


Parameters:

level – determines level of the trigger system

TRIGGER_LEVEL_PRIMARY – primary level

TRIGGER_LEVEL_SECONDARY – secondary level

amount – amount of trigger events necessary to start acquisition


Return value: -

3.3.7. SetTriggerLength

Sets minimal length of valid trigger event.

void __declspec(dllimport) __stdcall SetTriggerLength(int level, int samples);


Parameters:

level – determines level of the trigger system

TRIGGER_LEVEL_PRIMARY – primary level

TRIGGER_LEVEL_SECONDARY – secondary level

samples – minimal length of the valid trigger event from 8 to 131068 with step

of 4. Value 0 turns the digital filter off.

Return value: -

3.3.8. SetTriggerMode

Sets

trigger

mode.

void __declspec(dllimport) __stdcall SetTriggerMode(int mode);


Parameters:

mode – trigger mode

TRIGGER_MODE_AUTO – in case, that the trigger event doesn’t

occur for longer time, the acquisition starts anyway

TRIGGER_MODE_NORMAL – the acquisition starts only on valid

trigger event

TRIGGER_MODE_MANUAL – the acquisition starts immediately after

call of StartMeasurement function

- 17 -