Settriggercount, Settriggerlength, Settriggermode – Dataman 570 Series User Manual
Page 17

Development kit for DATAMAN 570 series
Programmer’s Guide
Parameters:
channel – determines channel
CHANNEL_A – channel A
CHANNEL_B – channel B
level – determines quantization level (0 to 255), which will be considered as
threshold
Return value: -
3.3.6. SetTriggerCount
Sets amount of trigger events necessary to start acquisition on the selected trigger
level.
procedure SetTriggerCount(level:integer;amount:integer);stdcall;external
'm570drvdk.dll';
Parameters:
level – determines level of the trigger system
TRIGGER_LEVEL_PRIMARY – primary level
TRIGGER_LEVEL_SECONDARY – secondary level
amount – amount of trigger events necessary to start acquisition
Return value: -
3.3.7. SetTriggerLength
Sets minimal length of valid trigger event.
procedure SetTriggerLength(level:integer;samples:integer);stdcall;external
'm570drvdk.dll';
Parameters:
level – determines level of the trigger system
TRIGGER_LEVEL_PRIMARY – primary level
TRIGGER_LEVEL_SECONDARY – secondary level
samples – minimal length of the valid trigger event from 8 to 131068 with step
of 4. Value 0 turns the digital filter off.
Return value: -
3.3.8. SetTriggerMode
Sets
trigger
mode.
procedure SetTriggerMode(mode:integer);stdcall;external 'm570drvdk.dll';
Parameters:
mode – trigger mode
- 17 -