2.3. Operation

NOTICE!

Only operate d&b loudspeakers with a correctly configured d&b

amplifier, otherwise there is a risk of damaging the loudspeaker

components.

Application

Setup

Cabinets per

channel

Yi-SUB

Y-SUB

2

Within applicable amplifiers, the controller setup is available in

Dual Channel or Mix TOP/SUB mode.

2.3.1. Controller settings

For acoustic adjustment the 100 Hz function can be selected.

100 Hz circuit
If the 100 Hz circuit is selected, the upper operating frequency of

the system is reduced from 140 Hz to 110 Hz.

2.4. Technical specifications
Yi-SUB system data

Frequency response (–5 dB standard)

39 Hz - 140 Hz

Frequency response (–5 dB 100 Hz mode)

39 Hz - 110 Hz

Max. sound pressure (1 m, free field)
with D80/D12/D6

134 dB/131 dB/128 dB

(SPLmax peak, pink noise test signal with crest factor of 4)

Yi-SUB loudspeaker

Nominal impedance

8 ohms

Power handling capacity (RMS/peak 10 ms)

600/2400 W

Components

1 x 18" driver
1 x 12" driver

Connections

2 x NL4 M

1 x screw terminal (ST - up to 4 mm

2

/AWG 11)

Optional fixed cable (PG):

H07-RN-F, 2 x 2.5 mm

2

(AWG 13), 5.5 m (18 ft)

Pin assignment

NL4 M: 1+/1–

Fixed cable (PG): Brown: (+) / Blue: (–)

Weight

49 kg (108 lb)

Yi-SUB frequency response, standard and 100 Hz mode