Operation, Controller settings, Technical specifications – d&b Yi-SUB User Manual
Page 8
2.3. Operation
NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Application
Setup
Cabinets per
channel
Yi-SUB
Y-SUB
2
Within applicable amplifiers, the controller setup is available in
Dual Channel or Mix TOP/SUB mode.
2.3.1. Controller settings
For acoustic adjustment the 100 Hz function can be selected.
100 Hz circuit
If the 100 Hz circuit is selected, the upper operating frequency of
the system is reduced from 140 Hz to 110 Hz.
2.4. Technical specifications
Yi-SUB system data
Frequency response (–5 dB standard)
39 Hz - 140 Hz
Frequency response (–5 dB 100 Hz mode)
39 Hz - 110 Hz
Max. sound pressure (1 m, free field)
with D80/D12/D6
134 dB/131 dB/128 dB
(SPLmax peak, pink noise test signal with crest factor of 4)
Yi-SUB loudspeaker
Nominal impedance
8 ohms
Power handling capacity (RMS/peak 10 ms)
600/2400 W
Components
1 x 18" driver
1 x 12" driver
Connections
2 x NL4 M
1 x screw terminal (ST - up to 4 mm
2
/AWG 11)
Optional fixed cable (PG):
H07-RN-F, 2 x 2.5 mm
2
(AWG 13), 5.5 m (18 ft)
Pin assignment
NL4 M: 1+/1–
Fixed cable (PG): Brown: (+) / Blue: (–)
Weight
49 kg (108 lb)
Yi-SUB frequency response, standard and 100 Hz mode
d&b Yi-SUB Manual 1.1 en
8