beautypg.com

d&b Bi6-SUB User Manual

Page 6

background image

d&b LoadMatch
Starting with the D80 amplifier, the LoadMatch function enables

the amplifier to electrically compensate for the properties of the

loudspeaker cable used without the need for an additional sense

wire. For applicable loudspeakers, LoadMatch is therefore

independent of the connector type used.

Fixed cable connection
The Bi6-SUB loudspeaker is supplied with a cover plate

[1] and a

rubber grommet feed through

[2]. For indoor operation, these

items can be used to hide the connector panel, if required. For

unprotected outdoor operation, the connector panel must be

covered, i.e. both items must be used to achieve an IP degree of

protection of IP34.

To install the fixed cable connection, proceed as follows:

Tools required: Philips screw driver (#PH2).

1. Remove the knockout opening in the cover plate

[1] and

attach the rubber grommet

[2] correspondingly.

2. Insert the connection cable through the rubber grommet.
3. Undo the four screws of the connector panel.
4. Connect the cable wires to the screw terminal.

Þ Observe the correct polarity!

5. Push the cover plate towards the connector panel until it fits

into place.

6. Finally fix the cover plate together with the connector panel

using all screws.

Step 2

Step 3

Step 4/5

Step 6

Installing the fixed cable connection

Step 1

d&b Bi6-SUB Manual 1.1 en

6