2.3. Operation

NOTICE!

Only operate d&b loudspeakers with a correctly configured d&b

amplifier, otherwise there is a risk of damaging the loudspeaker

components.

Application

Setup

Cabinets per

channel

B6-SUB

B6-SUB

2

Within applicable amplifiers, the controller setup is available in

Dual Channel or Mix TOP/SUB mode.

2.3.1. Controller settings

For acoustic adjustment the 100 Hz and CSA function can be

selected.

100 Hz circuit
If the 100 Hz circuit is selected, the upper operating frequency of

the system is reduced from 140 Hz to 110 Hz.

It can be used when actively driven B6-SUB subwoofers are used

to supplement TOP cabinets operated in full range mode, for

example in a distributed sound system. The 100 Hz mode can also

be used to compensate for the effect of close coupling between the

B6-SUB and TOP cabinets operated in CUT mode.

CSA circuit
CSA (

Cardioid Subwoofer Array) mode enables the combination

of three or multiples of three subwoofer cabinets into an array that

produces exceptional low frequency directivity control.

The amplifier channel for the center subwoofer of the array, which

is physically pointed to the rear, has CSA selected. The forward

facing cabinets are driven with an amplifier channel set in the

standard mode. The resulting cardioid behavior of the array will

significantly reduce the energy radiated to the rear.

For further information please refer to the d&b TI 330 Cardioid

Subwoofer Array, which is available for download at

www.dbaudio.com

.

CSA Stack (Example)

d&b B6-SUB Manual 1.1 en

6