Addressing – CUE inputCUE User Manual
Page 7

User Manual inputCUE
www.cuesystem.com
Page 7 of 14
4. Addressing
The BUTTON_ID transmitted by the inputCUE is calculated according formula below.
BUTTON_ID = Offset + Input #
Offset
= 8 * ADDRESS
The lowest BUTTON_ID is generated by the input marked 1 the highest BUTTON_ID is generated by
the input marked 8.
The ADDRESS of the inputCUE is binary coded by DIP switch. The range is 0 to 255.
Switch view
Switch nr.
Function
SW1
ADDRESS bit 0
SW2
ADDRESS bit 1
SW3
ADDRESS bit 2
SW4
ADDRESS bit 3
SW5
ADDRESS bit 4
SW6
ADDRESS bit 5
SW7
ADDRESS bit 6
ON
1
7
6
5
4
3
2
8
SW8
ADDRESS bit 7
ADDRESS
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
0
OFF OFF OFF OFF OFF OFF OFF OFF
1
ON OFF OFF OFF OFF OFF OFF OFF
2
OFF ON OFF OFF OFF OFF OFF OFF
3
ON ON OFF OFF OFF OFF OFF OFF
4
OFF OFF ON OFF OFF OFF OFF OFF
5
ON OFF ON OFF OFF OFF OFF OFF
6
OFF ON ON OFF OFF OFF OFF OFF
7
ON ON ON OFF OFF OFF OFF OFF
8
OFF OFF OFF ON OFF OFF OFF OFF
9
ON OFF OFF ON OFF OFF OFF OFF
...
255
ON ON ON ON ON ON ON ON
In the table below there is Input ID range for each address.
ADDRESS
BUTTON_ID range
0 1 8
1 9 16
2 17 24
3 25 32
4 33 40
...
255 2041 2048