4. Addressing

Each unit connected to the CUEwire bus must have its unique address. These addresses for
touchpanels and keyboards are set in configuration and are called „panel addresses“. The same type
of address is set for each sensorCUE-W. Its value must be unique for each unit on the CUEwire bus.

The ADDRESS of the sensorCUE-W is binary coded by DIP switch located on the rear panel.

The ADDRESS can be set in the range 1 to 127. Default ADDRESS is 15.

Switch view

Switch nr.

Function

Address bit’s weight

SW1

ADDRESS bit 0

1

SW2

ADDRESS bit 1

2

SW3

ADDRESS bit 2

4

SW4

ADDRESS bit 3

8

SW5

ADDRESS bit 4

16

SW6

ADDRESS bit 5

32

SW7

ADDRESS bit 6

64

SW8

Not used

Not used

ADDRESS

SW1

SW2

SW3

SW4

SW5

SW6

SW7

1

ON OFF OFF OFF OFF OFF OFF

2

OFF ON OFF OFF OFF OFF OFF

3

ON ON OFF OFF OFF OFF OFF

4

OFF OFF ON OFF OFF OFF OFF

5

ON OFF ON OFF OFF OFF OFF

6

OFF ON ON OFF OFF OFF OFF

7

ON ON ON OFF OFF OFF OFF

8

OFF OFF OFF ON OFF OFF OFF

9

ON OFF OFF ON OFF OFF OFF

… … … … … … …

15

ON ON ON ON OFF OFF OFF

… … … … … … …

126

OFF ON ON ON ON ON ON

127

ON ON ON ON ON ON ON