beautypg.com

14 flow diagrams, Figure 8. flowchart preamplifier, Figure 9. flowchart protection circuit – Dynaudio BX30 User Manual

Page 14: Bx30 owner’s manual

background image

BX30 Owner’s Manual

14

Flow diagrams

Right

24 dB/oct

120 Hz

Right

a

a

b

b

Level

Phase 0°-180°

Line receiver

Limiter

Passiv limiter

Input relay

Power Amplifier

Speaker relay

Fix level

+4 dBm

-10 dBm

Mute

Phase +180°

24 dB/oct

10 Hz

Subsonic

Left

Left

24 dB/oct

95 Hz

24 dB/oct

80 Hz

Low pass

Speaker

Buffer

L+

L-

R+

R-

b

Left

Line driver

24 dB/oct

High pass 95 Hz

Output switch

Right

24 dB/oct

L+

L-

R+

R-

c

e

d

f

g

Right

Left

Equalizer

= also adjustable with a tool

Right

Left

IN XLR

OUT XLR

VCA

b

Output relay

b

60°

h

Temperature

sensor

Figure 8. Flowchart preamplifier

3 seconds

Timer

0 = fault

0 = fault

0 = fault

0 = fault

0 = fault

0 = fault

V++ ±10%

V-- ±10%

VCC ±5%

VEE ±5%

DC at amplifier

Temperature > 60°

Bass level

Red

Protection

indicator

Green

VU

indicator

h

Green; input

Red; input overload

b

f

g

Front of cabinet

Front of cabinet

Timer

d

e

Input level right

Input level left

attack 3s

hold 10s

OR

AND

Limiter

indicator

c

Red; limiting

Buffer

Comparator

Comparator

1 = no fault

= also adjustable with a tool

Reset

Limiter active

OR

0 = fault

Startup

Comparator

Comparator

Figure 9. Flowchart protection circuit