• Forced passive arming On or Off. If your security system is pro-
grammed for passive arming and the forced passive arming fea-
ture has been programmed on, the system will passively arm after
one hour, even if a protected entry has been left open. Forced
passive arming ensures that the system will be armed if a door has
accidentally been left ajar when leaving the vehicle.
When the system passively arms after one hour, the entry point that
has been left open, and anything connected to the same zone, is
bypassed and cannot trigger the system. However, the remaining
inputs to the system are fully operational.
• Full trigger response 30 or 60 seconds: This determines how long
the full triggered sequence lasts. Some states have laws regulating
how long a security system can sound before it is considered a
nuisance.
If your installer is programming the security system with the Di-
rected Bitwriter, the full triggered response can be programmed
for any duration ranging from 1 to 180 seconds.
• Siren tones and chirp volume. The output of the Revenger™ Soft
Chirp™ siren consists of six different tones in sequence. Any of
these tones can be eliminated by a dealer, resulting in a unique,
easily identifiable siren sound. The chirps can be either full volume
or 6 decibels quieter than the full alarm blast.
• 12, 24, or 60 minute run time. your system can be programmed
to allow the vehicle to run for 12, 24, or 60 minutes when remote
started. Can be set up to minute increments by your installer.