CLEARANCES TO COMBUSTIBLE MATERIALS
It is of utmost importance that the clearances to combustible material mentioned on your wood stove
certification plate be scrupulously respected upon installation.
CLEARANCES
Model
Back Wall
Side Walls
Corners
* Height
Baron 1880sp
18" / 610 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Baron 2000sp
24" / 610 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Baron 1880sp
with envelope
15" / 381 mm
26,5’’ / 673mm
26,5’’ / 673mm
7' / 2,13 m
Baron 2000sp
with enveloppe
15" / 381 mm
26,5’’ / 673mm
26,5’’ / 673mm
7' / 2,13 m
Cassandra
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Compak
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Contempro 1300
14" / 355 mm
26" / 660 mm
15" / 381 mm
7' / 2,13 m
Contempro 1600
12" / 305 mm
24" / 610 mm
15" / 381 mm
7' / 2,13 m
Contempro 2000
12" / 305 mm
24" / 610 mm
15" / 381 mm
7' / 2,13 m
CS 1200
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Gemini 1200
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Gemini 1500
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Jasper
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Klondike
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Little Sawman
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Lorraine
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
ML
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Patriarch
48" / 1219 mm
36" / 914 mm
24" / 610 mm
7' / 2,13 m
RC
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Nordic
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Sawman
16" / 406 mm
30" / 762 mm
30" / 762 mm
7' / 2,13 m
Sawyer
36" / 914 mm
38" / 965 mm
24" / 610 mm
7' / 2,13 m
Settler
32" / 813 mm
32" / 813 mm
22" / 559 mm
7' / 2,13 m
Whistler, DLX
16" / 406 mm
16" / 406 mm
16" / 406 mm
7' / 2,13 m
Single Pipe / Double
Single Pipe / Double
Single Pipe / Double
Classic
16" (406mm) / 12" (305mm)
22" (559mm) / 22" (559mm)
11" (279mm) / 11" (279mm)
7' / 2,13 m
Fx 3000
14 1/2"(368mm) / 4 /2"(114mm)
12" (305mm) / 12" (305mm)
4" (102mm) / 4" (102mm)
7' / 2,13 m
Royal Comfort
17" (432mm) / 8" (203mm)
13" (330mm) / 13" (330mm)
16”(406mm) / 10”(254mm)
7' / 2,13 m
* Height, from stove base to ceiling.
You may decrease these clearances by installing heat radiation shields between the walls or the ceiling and
the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid
non-combustible sheet or a masonry wall. The installation standards of such heat radiation shields are listed
on the following page.
IT IS STRICTLY FORBIDDEN TO PLACE WOOD WITHIN THE MINIMUM CLEARANCES.