Captive screw – Atlona AT HDTX IR User Manual
Page 5
5
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Captive Screw
Connecting
Captive screw connectors are an added feature on the HD Extenders. The Captive screw connectors allow
you to cut cables down to a suitable length, reducing cable clutter, and provides a more reliable connection.
The captive screw connectors have a contact bar that is moved to compress the wire to the top contact
plate. Use the screws at the top of the connector to compress the wire against the contact plate.
When connecting the cables to the female captive screw connector it is important that the wires be
terminated correctly. The female captive screw connector (see picture A) has a contact plate at the top and
must have the wires touching it for signal to pass. When wired correctly (see picture B) the signal will pass,
incorrectly (see picture C) no signal will pass.
For your convenience the cables do not come pre-terminated. Each item, whether it’s an IR receiver (picture
1), IR emitter (picture 2), or power cable (picture 3), will have wires exposed. Each wire is encased in a
different colored cover. Female captive screw connectors are included: Power (see picture 4) and IR (see
picture 5).
IR pin outs have been included for the included IR emitter and IR receiver (see picture 6 & 7). The wires are
colored for each pin (see picture 8 and 9).
To ensure the power cable isn’t too long, a captive screw connector has been included. The pin out (see
picture 10) and the wire configuration (see picture 11 and 12) are shown below.
White: - Red:+
Black: - White: +
Red: PWR White: IR Black:
╧
4
2
3
1
Power
IR
Clockwise
Counter
Clockwise
Turn the screws clockwise to
raise the contact bar to the upper
contact plate and hold the wires
in place.
Turn the screws counter clockwise
to lower the contact bar to release
the wires.
5
6
7
8
9
11
A
B
C
-
+
Emitter
PWR IR
╧
Receiver
- +
10
12