7, Feedback commands (from a controller)
The 8 ASCII feedback commands are send after receiving the command from a controller
Item
Command
Function
Description
1
6%$/21$.
Power on
Responses the system power.
On command to the controller
2
6%$/2)$.
Power off
Responses the system power.
Off command to the controller
3
6%8'[[
Channel 1 updated
Changes the 1
st
output signal.
xx is the selected source
[[
4
6%8'[[
Channel 2 updated
Changes the 2
st
output signal.
xx is the selected source
[[
5
6%8'[[
Channel 3 updated
Changes the 3
st
output signal.
xx is the selected source
[[
6
6%8'[[
Channel 4 updated
Changes the 4
st
output signal.
xx is the selected source
[[
7
6%6<6/2.
Lock on
Is locked on
8
6%6<68/.
Lock off
Is released
9
6%567$&.
Reset
Responses the reset command.
10
6%67$7$.
Status asknowledge
Responses the ask status
Command to the controller
Remark: The device responds to one feedback command for every request except the
th
, 1/2
th
, IN/OUT
state, 7/8
th
command sequentially.
Note: Responses IN/OUT state command: SBUD0000XXYY
input port XX=> (01, 02, ..., 06)
output port YY=> (01, 02, ..., 06)