3
SETTING UP CAT5E/6/7
NO POWER ON THE EXTENDERS
IMAGE IS BAD/FLICKERS
CAT5E or higher is recommended for use with the Atlona AT-PROHD48M-SR. If cables are run in the
walls make sure to stay away from light fixtures, electrical boxes, fluorescent lights, and any or other
electrical cables to reduce and prevent signal degradation. T568B termination needs to be used for this
device.
Pin T568A Pair T568B Pair Wire
T568A Color
T568B Color
Pins on plug face
(socket is reversed)
1
3
2
tip
white/green stripe
white/orange stripe
2
3
2
ring
green solid
orange solid
3
2
3
tip
white/orange stripe white/green stripe
4
1
1
ring
blue solid
blue solid
5
1
1
tip
white/blue stripe
white/blue stripe
6
2
3
ring
orange solid
green solid
7
4
4
tip
white/brown stripe
white/brown stripe
8
4
4
ring
brown solid
brown solid
If the unit is not powering-on please double check the surge protector/ outlet that the unit is connected
to. A Volt Meter can also be used to check the unit and the power supply needs to be outputting 12V
DC (110/240v universal).
1 2 3 4 5 6 7 8
Pin Position
The image flickers, goes in and out, or there is snow like affect, there are multiple reasons for this is-
sues. Check all the connections HDMI and CAT5E/CAT6 and make sure they are fully connected and
are not loose. Check to see the CAT5E/CAT6/CAT7 terminations are fully crimped. CAT5E/CAT6/CAT7
is pick¬ing interference from other cables in the wall. Shielded cables are recommended to be run in
the walls. CAT5E/CAT6/CAT7 wall plates or CAT5 terminal blocks should not be used as they can also
cause inter¬ference in the signal; it needs to be connected with cables direct. The CAT5E/CAT6/CAT7
cables should not exceed the distance they are meant to be run at. It is important to use T568B termina-
tion on the CAT5E/CAT6/CAT7 cables.