OPERATING HEATER

Continued

Figure 21 - Control Knob(s) and Ignitor

Button Locations

Ignitor Button

Control Knob Rear Burner

Control Knob

Figure 22 - Pilot

(Propane/LP)

Pilot Burner

Thermocouple

Figure 23 - Pilot

(Natural)

Ignitor
Electrode

Pilot Burner

Thermocouple

5. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds (see Figure 21).

Note: You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

6. With thermostat control knob pressed in,

press and release ignitor button. This will

light pilot. The pilot is attached to the front

burner. If needed, keep pressing ignitor

button until pilot lights.

Note: If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one (1) minute for system to

reset before lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The front burner

should light. Set control knob to any heat

level between HI and LO.

9. To light the rear yellow flame burner, push

in and turn rear burner control knob coun-

terclockwise

to the ON position.

CAUTION: Do not try to adjust

heating level of rear burner. Rear

burner control knob should be in ON

or OFF positions only. Do not oper-

ate with rear burner control knob

between ON or OFF positions.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn rear burner control knob clockwise

to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1. Turn control knob clockwise

to the

PILOT position.

2. Turn rear burner control knob clockwise

to the OFF position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any

comfort level between HI and LO. The ther-

mostat will gradually modulate the heat output

and flame height from higher to lower settings

or pilot, in order to maintain the comfort level

you select. The ideal comfort setting will vary

by household depending upon the amount of

space to be heated, the output of the central

heating system, etc.
Note:

Selecting the HI setting with the control

knob will cause the burner to remain fully on,

without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions, starting on page 16.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow steps 8 and 9

under Lighting Instructions, column 1.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.