American Weigh Scales (AWS) CP2-600 User Manual
Page 5
remove any items from the weighing platform and
press the
M key again to re-zero the scale.
VII. Calibration
Calibration and adjustment are performed at the factory.
However, the weighing range can shift slightly during
shipping. Also, due to changes in local acceleration of gravity
around the world, adjustment is recommended when moving
the scale from one location to another. To check calibration:
1. Place the required calibration weight on the scale
and note the displayed value.
2. If the displayed value is not within acceptable
tolerance (see chart below), adjustment is required.
Model
Acceptable
Tolerance (±)
Calibration
Weight
Recommended
Accuracy Class
CP2-100
0.02g
100g
OIML M2
CP2-600
0.2g
500g
OIML M2
VIII. Adjustment
1. While the scale is turned OFF, press and hold the
M key.
2. While continuing to hold the
M key, tap the key to
turn the scale ON.
3. The display will show the internal statement number.
4. Press the key again. The display will show “Zero”
followed by the required calibration weight.
5. Place the required calibration weight on the center of
the scale platform and press the key again.
6. The display will show “F” for finished. You may
remove the calibration weight and turn off the scale.