background image

4. To return to normal weight display (gross weight),

remove any items from the weighing platform and

press the

ON/OFF/TARE key again to re-zero the

scale.

VII. Calibration
Calibration and adjustment are performed at the factory.

However, the weighing range can shift slightly during

shipping. Also, due to changes in local acceleration of gravity

around the world, adjustment is recommended when moving

the scale from one location to another. To check calibration:

1. Place the required calibration weight on the scale

and note the displayed value.

2. If the displayed value is not within acceptable

tolerance (see chart below), adjustment is required.

Model

Acceptable

Tolerance (±)

Calibration

Weight

Recommended

Accuracy Class

QS-500

0.2g

500g

OIML M2

VIII. Adjustment

1. With the scale OFF, press and hold the

MODE key

then press the

ON/OFF/TARE key until the display

shows a random number. Now release both keys.

2. Press the

ON/OFF/TARE key again. The display will

show “Zero” then “500.0g”.

3. Gently place a 500g weight on the center of the

platform and press the

ON/OFF/TARE key again.

The LCD will display “PASS” then “500.0”.

4. Calibration is complete. If the scale shows “ H ”, an

error has occurred - Turn off the scale and repeat

steps 1 to 3 above.

This manual is related to the following products: