beautypg.com

American Weigh Scales (AWS) MSC-650 User Manual

Page 5

background image

be weighed. The display will show the net weight of

the contents.

4. To return to normal weight display (gross weight),

remove any items from the weighing platform and
press the

key again to re-zero the scale.

VIII. Calibration
Calibration and adjustment are performed at the factory.

However, the weighing range can shift slightly during

shipping. Also, due to changes in local acceleration of gravity

around the world, adjustment is recommended when moving

the scale from one location to another. To check calibration:

1. Place the required calibration weight on the scale

and note the displayed value.

2. If the displayed value is not within acceptable

tolerance (see chart below), adjustment is required.

Model

Acceptable

Tolerance (±)

Calibration

Weight

Recommended

Accuracy Class

MSC-200

0.02g

200g

OIML M2

MSC-650

0.2g

500g

OIML M2

IX. MSC-200 Adjustment

MSC-200 Calibration Adjustment

1. Turn the scale OFF.
2. While holding the M key, tap the

key to turn the

scale on then release both keys.

3. The display will show a random number, press the [

M ] key again.

4. The display will flash “200.00”. Place the required

weight on the platform and wait for 3 seconds.

5. The display will show “PASS” and “200.00”. Remove

This manual is related to the following products: