beautypg.com

American Weigh Scales (AWS) CHROME-1KG User Manual

Page 5

background image

4. To return to normal weight display (gross weight),

remove any items from the weighing platform and

press the

TARE key again to re-zero the scale.

VII. Using the Counting Feature

1. Press the

ON/OFF key to turn the scale on.

2. Place a sample quantity of the items being weighed

on the platform. This quantity should either be 25,

50, 75, or 100 pieces.

3. Once the weight is stable, press and hold the

PCS

key to enter counting mode setup.

4. The current sample size will be displayed on the

LCD (ie. “P 25”).

5. Press the

MODE key to change it between 25, 50,

75, or 100 and press

PCS to confirm. The count will

be displayed on the LCD. You may now add more

items. As items are remove items and the count will

update automatically.

VIII. Calibration
Calibration and adjustment are performed at the factory.

However, the weighing range can shift slightly during

shipping. Also, due to changes in local acceleration of gravity

around the world, adjustment is recommended when moving

the scale from one location to another. To check calibration:

1. Place the required calibration weight on the scale

and note the displayed value.

2. If the displayed value is not within acceptable

tolerance (see chart on the next page), adjustment

is required.