Dimensions – ABUS Technologies HART? Block Temperature Transmitter User Manual
Page 5

ABUS TECHNOLOGIES INC.
5
HART
Block
ENVIRONMENT CONDITIONS
Ambient temperature:
-40 ~ 85°C (-40°F ~ 185°F)
Storage temperature:
-40 ~ 100°C (-40°F ~ 212°F)
Condensation:
Allowable
Degree of protection:
IP00
Shock and vibration resistance:
4g/2 ~ 150 Hz as per IEC 60 068-26
Electromagnetic compatibility (EMC): Interference immunity and interference emission
according to GB/T17626.2 (1998), compliance with IEC
61 000-4-3 (1995).
Installation Instruction:
Installation angle: no limit.
MATERIALS
Dimensions:
Dia. 44 mm x 22.5 mm
Materials:
Housing: PC, Plotting: epoxy
Weight: Approx.
33.5 g
Maximum measured error
INPUT
TYPE
MEASUREMENT ACCURACY
Resistance thermometer RTD
Pt100, Ni100
Pt500, Ni500
Pt1000, Ni1000
Cu50
Cu100
0.2 K or 0.08 %
0.5 K or 0.20 %
0.3 K or 0.12 %
0.2 K or 0.08 %
0.3 K or 0.12 %
Thermocouple TC
K, J, T, E
N
S, B, R
Typ.0.5K or 0.08 %
Typ.1.0K or 0.08 %
Typ.2.0K or 0.08 %
Resistance transmitter (Ω)
0 to 400 Ω
0 to 2000 Ω
0 to 10000 Ω
±0.1 Ω or 0.08 %
±1.5 Ω or 0.12 %
±7.5 Ω or 0.20 %
Voltage Transmitter (mV)
-10 to 75 mV
-100 to 100 mV
-100 to 500 mV
-100 to 2000 mV
±20 μ V or 0.08 %
±20 μ V or 0.08 %
±30 μ V or 0.08 %
±50 μ V or 0.08 %
3. DIMENSIONS