PT

2.2 Technical Parameters

Accuracy:

±0.25%FS (BFSL)

±0.5%FS (limit point calibration)

Ranges:

Absolute:

0…1 to 0…50 bar, 0…15 to 0…750 psi

Vacuum:

(-1)… bar, (-15)…0 psi

Gauge:

0…100mB to 0…1000 bar, 0…1.5 to 0…15000 psi

Output:

0...5 V, 0...10 V, 0.5...4.5 V, 4...20 mA

(Customized On request)

Power Supply:

24Vdc (10~36Vdc)

Maximum Pressure:

1.5 x F.S.

Adjustability Zero / Span:

± 10 % using potentiometers inside.

Electrical Connections:

M12 connector, Five Pin bendix connector, Hirschman Type or Direct

down-lead.

Process Connection:

G1/4, M20 x 1.5, 1/4NPT (Customized On request)

Pressure Inlet:

All media compatible with stainless steel 316

Operating temperature:

-40 ~ 85

°C (125°C for short durations) * Higher range, on request.

Ambient temperature:

-20 ~ +80°C

Wetted Parts:

SS 316L / Al2O3 / NBR

Case:

Stainless steel

Housing:

Stainless steel, protection class IP65.

3. DIMENSIONS