I n 0 0 d i p 0, Authorised distributor, Limited warranty – ABUS Technologies USI-C Universal Smart Isolator Hand-Held Configurator User Manual
Page 2

MILLENNIUM INSTRUMENTS LIMITED
Authorised Distributor :
Works- F-12, Site-B, UPSIDC Industrial Area
Surajpur, Greater Noida, U. P. 201306
Tel. -
+91-11-22014325, 65094516
Fax.-
+91-11-22014326
E-Mail -
[email protected] [email protected]
,
WebSite - www.miepl.com, www.mil.org.in
Limited Warranty
The products are warranted to be free from defects in
materials and workmanship for a period of one (1) year from
the date of shipment, subject to the following terms and
conditions: Without charge, they will repair, replace, or refund
the purchase price at option products found to be defective in
materials or workmanship within the warranty period;
provided that:
! the product has not been subjected to abuse, neglect,
accident, incorrect wiring not our own, improper installation
or servicing, or use in violation of labels or instructions;
! the product has not been repaired or altered by anyone
except us;
! the maximum ratings label and serial number or date code
have not been removed, defaced, or otherwise changed;
! examination discloses, in the judgment of us, the defect in
materials or workmanship developed under normal
installation, use and service; and
! Our system is notified in advance of and the product is
returned to us transportation prepaid before expiration of
the warranty period.
THIS EXPRESS LIMITED WARRANTY IS IN LIEU OF AND
EXCLUDES ALL OTHER REPRESENTATIONS MADE BY
ADVERTISEMENTS OR BY AGENTS AND ALL OTHER
WARRANTIES, BOTH EXPRESS AND IMPLIED. THERE
ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY
OR OF FITNESS FOR A PARTICULAR PURPOSE FOR
GOODS COVERED HEREUNDER.
Input Selection (In)
Process Parameters
Precautions
I n
0 0
D i p
0
Set Value
00
01
02
03
04
05
06
07
10
11
12
13
14
15
17
20
21
22
23
24
25
26
27
Input Type
K
E
S
B
J
T
R
N
DC 0~20mV
DC 0~75mV
DC 0~200mV
DC 0~10V
DC 2~20V
DC 0~10mA
DC 4~20mA
Pt100
Cu100
Cu50
BA2
BA1
G
Pt100X
0 ~ 400 Ω
Input Range
0 ~ 1300 °C
0 ~ 900 °C
0 ~ 1600 °C
300 ~ 1800 °C
0 ~ 400 °C
0 ~ 1300 °C
0 ~ 1600 °C
0 ~ 1300 °C
-1999 ~ 9999 °C
-1999 ~ 9999 °C
-1999 ~ 9999 °C
-1999 ~ 9999 °C
-1999 ~ 9999 °C
-1999 ~ 9999 °C
-1999 ~ 9999
-199.9 ~ 600.0 °C
-50.0 ~ 150.0 °C
-50.0 ~ 150.0 °C
-199.9 ~ 600 °C
-199.9 ~ 600 °C
-199.9 ~ 600 °C
-19.99 ~ 99.99 °C
-1999 ~ 9999 °C
: Mode of anti-jamming,
please do not change the
value.
: Decimal Point Position
(dip)
: PV BIAS, Sensor
correction is made by
adding bias value to
measured value (PV)
Dip
L d o
0
L u p
0
O d o 1
0
O u p 1
1 3 0 0
E n d
8 0 1
O u t
: Input limiter [LOW] for
input, set scaling within
the input range [low]
(Ldo)
: Input limiter [HIGH] for
input, set scaling within
the input range [HIGH]
(LUP)
: Transaction range [Low]
(odo1)
Set “odo1”= “Ldo”
: Transaction range [High]
(ouP1)
Set “ouP1”= “LUP”
: Indicate year and month
of production date (End)
Example: It indicates
production date as
JAN, 2008
: Recommended Settings,
Please don’t change the
values, or it will affect
accuracy.
Ldo
Lup
Odo1
Oup1
End
Out
Production value
Press Set Key
PV/SV DISPLAY
1. When no parameter setting is required, after the values be
registered, Press “SET” key and “A/M” key simultaneously
to return the instruments to the PV/SV Display.
2. If the displayed value is changed, but not registered, Press
“SET” Key to register the respective value.