NOTE
A 15amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all
cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or the
fuse blows on a regular basis when the heater is operating. Additional appliances on the same
circuit may exceed the current rating of the circuit breaker.
WARNING
Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure
that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire,
electric shock or injury to persons.

Construction and electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electric shock and injury to persons.

Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric
shock or injury to persons, always use a licensed electrician.

SECURING CORD (VIEW FROM BACK)








SAFETY WALL STRAP

The Corner Standing Stove is designed to fit tightly into the corner of a room. This unit should
be as close to the wall as possible. This unit comes with a safety securing strap. It is
suggested that the safety strap be used if there are children in the vicinity of the Corner
Standing Stove.

SECURING INSTRUCTIONS

1. In the corner of the wall, measure up the wall 42”. From that point measure out to the

right or left 15”. Note: Keep as level as possible, mark location.

2. Drill a 1/8” diameter hole.
3. Insert the provided wall plug. (FIGURE 13)
4. Locate left or right side strap mounting hole (2 ¾” from the left or right front edge of

unit). (FIGURE 12)

5. Hold strap in your hand with looped end in your palm. Insert free end though support

hole and then through loop in the strap. (FIGURE 14)

6. Insert screw through pre-punched hole in strap and screw into wall anchor.
7. Push unit into corner.









FIGURE 11

Securing Strap

Power Cord

3