beautypg.com

Superline installation, 4 superline connections, 1 superline rear – Naim Audio SuperLine User Manual

Page 4: 4 cartridge loading, 5 cartridge load plug combinations

background image

2

SuperLine Installation

to amplifier power

supply output or to

Hi-Cap or Flatcap

power supply

Resistance

Capacitance

Comments

10kΩ

100pF

Internal load only. No plugs fitted.

10kΩ

1nF

No resistive plug fitted.

10kΩ

4.7nF

No resistive plug fitted.

10kΩ

10nF

No resistive plug fitted.

1kΩ

100pF

No capacitive plug fitted.

1kΩ

1nF

1kΩ

4.7nF

1kΩ

10nF

500Ω

100pF

No capacitive plug fitted.

500Ω

1nF

Note 1

4 SuperLine Connections

4.1 SuperLine Rear

to Supercap

power supply

phono input

sockets. Ch. 1

- left, Ch. 2 - right

BNC input

sockets. Ch.

1 - left, Ch. 2

- right

pick-up arm

ground

capacitive

load plug

socket

resistive

load plug

socket

3.4 Cartridge Loading

The resistive and capacitive input load presented by
the SuperLine to the pick-up cartridge can be adjusted
by inserting a combination of “load plugs” into the
appropriate sockets in the rear panel.

The appropriate load plug combination will depend on
both the manufacturer’s recommendations for the pick-up
cartridge in use and subjective preference.

Each load plug is constructed from a 5-pin DIN plug that
contains the appropriate passive components. A label on
each load plug identifies its load value.

Seven standard load plugs are supplied - four resistive
and three capacitive - to provide 20 combinations

(including the default input loads applied when no load
plugs are inserted). Table 3.5 lists the standard load plug
combinations.

Note:

In addition to the standard load plugs supplied, 470Ω

and 560Ω resistive plugs are also available on request.
Other values may also be created either by modifying
standard plugs or manufacturing new ones. Contact your
retailer or local distributor for more information.

Always ensure that resistive and capacitive load plugs are
inserted in the correct socket.

Note:

The SuperLine incorporates 10kΩ resistance and

100pF (0.1nF) capacitance loads internally. With no load
plugs fitted these values constitute the default load.

3.5 Cartridge Load Plug Combinations

Resistance

Capacitance

Comments

500Ω

4.7nF

500Ω

10nF

220Ω

100pF

No capacitive plug fitted.

220Ω

1nF

220Ω

4.7nF

220Ω

10nF

100Ω

100pF

No capacitive plug fitted.

100Ω

1nF

100Ω

4.7nF

100Ω

10nF

Note 1:

Approximates to a Naim ‘K’ load (560Ω and 1nF).

Note:

SuperLine output

is muted for 2 minutes
following switch-on to
allow its circuitry to reach
optimal status.