12 Amplifier Operation and Programmable Functions

The Nait XS 2 incorporates some programmable functions and operational nuances. These
are described in the following paragraphs.

12.1 Automatic Input Switching

With

Automatic Input Switching

engaged the appropriate

source input will be selected as soon as any handset
function for that (Naim) source component is operated. For
example, if the tuner input is selected and the cd play key
is pressed on the handset, the Nait XS 2 will automatically
switch to the cd input. Automatic Input Switching can be
programmed to operate on any combination of the

cd

,

tuner

,

hdd

and

av

input buttons.

To enable Automatic Input Switching, first switch the Nait XS
2 into program mode by pressing and holding the handset

prog

key (with the handset in preamplifier mode). The front

panel

mute

button will illuminate if automatic switching is

already enabled. If it is not enabled it can be switched on
by pressing the

mute

button.

With automatic switching enabled, pressing the

mute

button again will reveal the inputs selected for auto
switching by their indicators illuminating for a short time.
Repeated operation of the

mute

button will sequentially

select through each possible combination of

cd

,

tuner

,

hdd

and

av

inputs and auto switching disabled (all

indicators off). When the desired inputs selected for auto
switching are indicated, stop pressing the button.

Automatic Input Switching only becomes operational
on exit from program mode by pressing and holding the
handset

prog

key.

Note:

The Nait XS 2 will leave program mode automatically

if no control commands are received for five minutes.

Note:

In a few cases some further equipment configuration

may be required for auto switching to operate correctly.
Please contact your retailer or local distributor for advice.

12.2 Handset Volume Control

The remote handset

volume

keys provide some alternative

control characteristics. A short press and release of a key
will adjust by a preset “nudge”, while pressing and holding
the key will result in three seconds of slow adjustment
followed by continual fast adjustment.

Note:

The Nait XS 2 does not incorporate any facility for

channel balance adjustment.

12.3 Mute

Mute silences the outputs and can be selected or
deselected by pressing the front panel

mute

button or

remote handset

mute

key.

12.4 Display

The Nait XS 2 front panel button illumination can
be switched off by pressing the remote handset (in
preamplifier mode)

disp

function. Any subsequent handset

or front panel operation will temporarily restore the display.
A second operation of the

disp

function will restore the

display.

12.5 Switch-on

After switch-on the Nait XS 2 will remain muted for 30
seconds while control systems and circuits stabilise.

12.6 Remote Control

The Narcom 4 remote handset supplied with the
Nait XS 2 duplicates all configuration and control functions.
See Section 18 for more information.

12.7 Defaults

To restore all Nait XS 2 programmable settings to the
factory defaults press and hold the remote handset

disp

key while the unit is in program mode. The Nait XS 2 will exit
from program mode following this operation.

12.8 Fault Conditions

The Nait XS 2 will indicate fault conditions by flashing front
panel button buttons. The following table lists the fault
indications.

Fault

Flashing Button

Link Plug or Power Supply mute
Excess Temperature

cd

Excess

Current

tuner