Caution – Nexen Linear Actuator 912734 User Manual
Page 5

FORM NO. L-21036-D-0812
5
LIMIT SWITCH ADJUSTMENT
These actuators have nonadjustable internal limit switches that are factory pre-set for the maximum stroke length. For
applications that require less than the maximum stroke, install an external limit switch and connect it to the web guide controller.
PRODUCT NUMBERS
Linear Actuator / 900 lbs, 8 inch stroke ...................................................................................................................................912733
Linear Actuator / 900 lbs, 12 inch stroke ................................................................................................................................912734
SPECIFICATIONS
FIGURE 3
Lubricate
MAINTENANCE
NOTE: Refer to Figure 3
Apply a few drops of light machine oil to the actuating rod.
The frequency in which the Linear Actuator will require
lubrication depends upon the working environment.
Product
Number
912733
912734
Speed
[inches per second]
[mm per second]
.39
9.91
.39
9.91
Thrust
[lbs]
[newtons]
]
900
4000
900
4000
Stroke
[inches]
[mm]
8
200
12
300
Power
[volts]
[amps]
]
24 VDC
4.5 max
24 VDC
4.5 max
Environmental
Protection
Rating
IP51*
IP51*
*
Protected against the ingress of dust and dripping water
CAUTION
If there is a physical obstruction or stop that prohibits the use of the maximum stroke
length, then an external limit switch MUST be installed to interrupt the Linear Actuator's
movement before contact is made with the physical obstruction or stop.
Failure to use an external limit switch will damage both the Linear Actuator and the
web guiding mechanism.
If there is no physical obstruction to travel, then the nonadjustable, internal limit switches
may be used in their default position for maximum stroke length.