CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections,

internal and external to unit, for leaks after installing

or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a

leak. Apply noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1. Disconnect fireplace and its individual equipment shutoff valve

from gas supply piping system. Pressures in excess of 1/2 psig

(3.5 kPa) will damage fireplace gas regulator.

2. Cap off open end of gas pipe where equipment shutoff valve

was connected.

3. Pressurize supply piping system by either opening propane/LP

supply tank valve for propane/LP gas fireplace or opening main

gas valve located on or near gas meter for natural gas fireplace

or using compressed air.

4. Check all joints of gas supply piping system. Apply noncor-

rosive leak detection fluid to all joints. Bubbles forming show

a leak. Correct all leaks at once.

5. Reconnect fireplace and equipment shutoff valve to gas supply.

Check reconnected fittings for leaks.

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.)

Connecting Fireplace To Gas Supply

Checking Gas Connections

CAUTION: Use only new, black iron or steel

pipe. Internally-tinned copper tubing may be used in

certain areas. Check your local codes. Use pipe of

1/2" inside diameter or greater to allow proper gas

volume to fireplace. If pipe is too small, undue loss

of volume will occur.

Installation must include an equipment shutoff valve, union and

plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge

hook up. NPT tap must be upstream from fireplace (see Figure 31).
IMPORTANT:

Install main gas valve (equipment shutoff valve)

in an accessible location. The main gas valve is for turning on or

shutting off the gas to the appliance.
Check your building codes for any special requirements for locating

equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will

prevent excess sealant from going into pipe. Excess sealant in pipe

could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply

line as shown in Figure 31. Locate sediment trap/drip leg where it

is within reach for cleaning. Install in piping system between fuel

supply and fireplace. Locate sediment trap/drip leg where trapped

matter is not likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into fireplace gas con-

trols. If sediment trap/drip leg is not installed or is installed wrong,

fireplace may not run properly.

Figure 31 - Gas Connection

CSA Design-Certified

Equipment Shutoff Valve

with 1/8" NPT Tap*

3" Minimum

Approved Flexible

Gas Line

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

Natural - From

Gas Meter (5.5"

W.C. to 10.5"

W.C. Pressure)

Propane/LP

From External

Regulator (11"

W.C. to 14" W.C.

Pressure)

* The CSA design-certified equipment shutoff valve may be supplied

with the appliance or you can purchase it from your retailer.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver
• sealant (resistant to propane/LP gas, not provided)
1. Open lower louver door panel by gently pulling forward.
2. Route flexible gas line (provided by installer) from equipment

shutoff valve to fireplace. Route flexible gas supply line through

one of the access holes on side of fireplace.

3. Attach flexible gas line from gas supply to control valve (see

Figure 32).

4. Check all gas connections for leaks. See Checking Gas

Connections.

Figure 32 - Connecting Flexible Gas Line to Electronic Valve

1/2" NPT Incoming

Gas Line

Inlet Pressure Tap

Outlet Pressure Tap

Equipment

Shutoff Valve

Flexible Gas Line

Do NOT Kink

Note: Wire Connections Not Shown for Clarity